New Open-Source Dataset Provides 2,100 Radiation Dose Maps to Train Medical AI Models
Medicine

New Open-Source Dataset Provides 2,100 Radiation Dose Maps to Train Medical AI Models

Researchers simulate thousands of patient scans to build DosePET, an open-source repository designed to advance artificial intelligence in nuclear medicine dosimetry.

By Tariq Hassan
Published:
Email this Article
New Open-Source Dataset Provides 2,100 Radiation Dose Maps to Train Medical AI Models
Photo by Accuray on Unsplash

A new open-source dataset called DosePET provides 2,100 patient-specific radiation dose maps to help researchers train artificial intelligence models for nuclear medicine. The collection covers three common radiopharmaceuticals across seven different scanner models, addressing a major bottleneck in medical imaging research.

Personalized internal dosimetry calculates the exact radiation dose absorbed by individual organs and tissues during nuclear medicine procedures. While deep learning shows promise for predicting these radiation distributions quickly, progress has stalled because training artificial intelligence models requires massive collections of three-dimensional dose maps linked to patient anatomy. Generating these maps manually requires complex computer simulations that demand significant processing power and time.

To overcome this data shortage, Eleftherios Tzanis at the Karolinska Institutet and their colleagues constructed DosePET by running detailed physics simulations on thousands of existing scans. As described in a paper published on the arXiv preprint server, the research team processed 1,503 scans using fluorodeoxyglucose, 369 scans using prostate-specific membrane antigen tracer 1007, and 228 scans using gallium 68 labeled prostate-specific membrane antigen 11. These original scans came from five different institutions and included a total of 1,681 unique patients ranging in age from 11 to 90 years old.

How Did Researchers Simulate Thousands of Radiation Dose Maps?

The team built a automated processing pipeline that combined computerized tomography scans with positron emission tomography data. First, the computed tomography images were resampled onto the native positron emission tomography grid to create a voxelized patient phantom, which is a three-dimensional digital model representing tissue densities. Next, the researchers converted Hounsfield units into specific material compositions and mass densities using advanced simulation tools.

Radiation transport was then simulated using version 9.4 of the Geant4 Application for Tomographic Emission software. The simulations tracked ten million primary histories for each examination, totaling more than 1,500 hours of computer processing time on a high-performance system equipped with an Intel Core processor and an NVIDIA graphics card. Organ and tissue segmentations were automatically generated using a tool called TotalSegmentator, producing 117 binary masks for every patient study.

Figure 1: DosePET generation workflow. Quantitative PET/CT examinations were selected from ENHANCE.PET and PSMA-PET-CT-Lesions. The CT was resampled to the PET grid to define the voxelized phantom, and PET concentrations were converted to voxel activities for the source. GATE generated the dose field. TotalSegmentator used the original CT to provide anatomical masks for regional extraction. Study folders contain dose maps, anatomical masks, dose reports and metadata. Python tools support downloading and map conversion.
DosePET generation workflow. Quantitative PET/CT examinations were selected from ENHANCE.PET and PSMA-PET-CT-Lesions. The CT was resampled to the PET grid to define the voxelized phantom, and PET concentrations were converted to voxel activities for the source. GATE generated the dose field. TotalSegmentator used the original CT to provide anatomical masks for regional extraction. Study folders contain dose maps, anatomical masks, dose reports and metadata. Python tools support downloading and map conversion. Credit: Eleftherios Tzanis et al. / arXiv

What Data Files Are Included in Each Patient Study Folder?

Each individual study folder in the open-source repository contains a compressed Neuroimaging Informatics Technology Initiative dose map, 117 binary anatomical masks, and a comma-separated values report detailing regional dosimetric quantities. The reports list mean absorbed doses integrated from scan time to infinity, spatial dose standard deviations, dose conversion factors, and scan-time dose rates. Additional metadata files record administered activity, patient body weight, acquisition times, and radionuclide half-lives.

The highest median absorbed doses varied depending on the radiopharmaceutical tracer used. For fluorodeoxyglucose scans, the urinary bladder received the highest median dose at 15.22 milligray, followed by the brain at 10.77 milligray and the trachea at 9.85 milligray. For the prostate-specific membrane antigen 1007 tracer, the gallbladder, right kidney, and liver showed the highest median doses. For gallium 68 prostate-specific membrane antigen 11, the right and left kidneys received the highest median doses at 23.03 and 21.80 milligray, respectively.

What Are the Limitations of the Current Radiation Model?

The authors note several technical boundaries in how the dose maps were calculated. The simulations assume physical radioactive decay alone without modeling biological clearance, meaning the maps do not account for how the body naturally metabolizes and excretes the radiopharmaceutical over time. Furthermore, the data only covers the imaged field of view, and the calculations exclude radiation exposure originating from the initial computed tomography scan itself.

Despite these constraints, the release provides essential benchmark data for the medical physics community. Python tools are included in the repository to allow researchers to selectively download data and convert the dose maps into scan-time dose-rate or dose-per-decay formats. The complete dataset is publicly available on Hugging Face for investigators developing predictive artificial intelligence models.

The study was posted to the arXiv preprint server on November 25, 2026.

Fact Checked

This article has been fact checked for accuracy, with information verified against reputable sources. Learn more about us and our editorial process.

Last reviewed on .

Article history

  • Latest version

Reference(s)

  1. Tzanis, Eleftherios. “DosePET: An Open-Source Dataset with 2100 Radiation Dose Maps for PET/CT.” arXiv.org <http://arxiv.org/abs/2611.34008v1>.

Cite this page:

Hassan, Tariq. “New Open-Source Dataset Provides 2,100 Radiation Dose Maps to Train Medical AI Models.” BioScience. BioScience ISSN 2521-5760, 26 November 2026. <https://www.bioscience.com.pk/en/subject/medicine/dosepet-an-open-source-dataset-with-2100-radiation-dose-maps-for-pet-ct>. Hassan, T. (2026, November 26). “New Open-Source Dataset Provides 2,100 Radiation Dose Maps to Train Medical AI Models.” BioScience. ISSN 2521-5760. Retrieved November 26, 2026 from https://www.bioscience.com.pk/en/subject/medicine/dosepet-an-open-source-dataset-with-2100-radiation-dose-maps-for-pet-ct Hassan, Tariq. “New Open-Source Dataset Provides 2,100 Radiation Dose Maps to Train Medical AI Models.” BioScience. ISSN 2521-5760. https://www.bioscience.com.pk/en/subject/medicine/dosepet-an-open-source-dataset-with-2100-radiation-dose-maps-for-pet-ct (accessed November 26, 2026).
End of the article